FIGURE 1:

TYPICAL INSTALLATION

The Inline System is designed to both increase a system's incoming pressure and to provide the system with constant
pressure across all outlets. See FIGURE 2 for a graphical representation of what a typical installation may look like.
FIGURE 2:
Water Supply
Ball
*Check
Valve
Valve
Optional Bypass
*NOTICE: If system plumbing does not have a backflow prevention device, a check valve is required on the incoming
water supply line.
NOTE: These optional components are shown in a typical installation diagram. They should be used at the installer's
discretion as required for particular applications.
MOTOR OVERLOAD PROTECTION NOTE: The drive electronics provide motor overload protection by preventing
motor current from exceeding the maximum Service Factor Amps (SFA). Motor overtemperature sensing is not provided
by the drive.
4
3.45"
10.43"
[ 87.7 ]
[ 265 ]
1-1/4" NPT
SUCTION
Inline System
Union
Flow
Coupling
Ball
Valve
ACCESS PANEL
ACCESS PANEL SCREWS
18.84"
[ 478.5 ]
17.32"
[ 439.9 ]
5 feet or Less
2 Gallon
Power
Union
Pressure
Check
Coupling
Valve
Shut-o
Switch
(optional)
Check
Valve
1.50"
[ 38.1 ]
INPUT
POWER
1-1/4" NPT
DISCHARGE
Pressure
Switch
Tank
Pressure
Gauge
Pressure
Relief
Valve
(Discharge into drain
rated for max pump
output at relief pressure)
Ball
Valve
To Home

Publicidad