4. TIME LEARNING - SET-UP
When the board is powered, if a SET-UP has never been performed or if the board requires it,
flashes on the display indicating that a SET-UP must be performed.
The connected accessories are always registered during SET-UP.BUS-2EASY The
BUS-2EASY encoders registered during the SET-UP must then be enabled via the
function (BASIC Programming).
Perform the SET-UP as follows:
All safety devices are disabled during SET-UP! Therefore, perform the operation and
prevent any transit in the leaf movement area.
If a system without an encoder is installed, the leaves will require mechanical stops.
1. Access BASIC programming and go to the
is released.
2. Verify that the gate leaves are closed. Otherwise, proceed as follows:
- Keep the -/R2 button pressed to close leaf 2
- Keep the +/R1 button pressed to close leaf 1
If the corresponding leaf opens when the +/R1 and/or -/R2 buttons are pressed,
disconnect the power and invert the phase wires of the corresponding motor
on the J2 terminal board, (terminals 2-3 for the leaf 1 motor and terminals 5-6
for the leaf 2 motor).
3. With the gate leaves closed, launch the SET-UP procedure by keeping buttons
S1
until
flashes on the display (approx. 3 sec).
+
and - . Leaf 1 begins its opening movement.
4. Release
Operation WITHOUT Encoder
Stop the movement by sending an OPEN
A pulse as soon as leaf 1 reaches the
mechanical stop.
S2
will flash on the display (only if 2 motors have been selected): leaf 2 begins its opening
5.
movement.
Operation WITHOUT Encoder
Stop the movement by sending an OPEN
A pulse as soon as leaf 2 reaches the
mechanical stop.
S3
6.
will flash on the display (only if 2 motors have been selected): leaf 2 begins its closing movement.
Operation WITHOUT Encoder
Stop the movement by sending an OPEN
A pulse as soon as leaf 2 reaches the
mechanical stop.
S4
will flash on the display: leaf 1 will begin its closing movement.
7.
E145
tL
--
--
function, and
Operation WITH Encoder
Leaf 1 will stop as soon as it reaches the me-
chanical stop. If there is no mechanical stop,
stop the leaf movement at the desired point by
sending an OPEN A pulse.
Operation WITH Encoder
Leaf 2 will stop as soon as it reaches the
mechanical stop. If there is no mechanical
stop, stop the leaf movement at the desired
point by sending an OPEN A pulse.
Operation WITH Encoder
Leaf 2 will stop as soon as it reaches the me-
chanical stop. If there is no mechanical stop,
stop the leaf movement at the desired point by
sending an OPEN A pulse.
8
will appear when the F button
+
and - pressed
732783 - Rev.C
S0
En