TROUBLESHOOTING AND SOLUTIONS FOR FAULTS
OCCURRING DURING OPERATION
Fault symptoms
The unit does not power on
The display keeps displaying 0.0
Reading of the measured values is not stable
The measured values show incorrect
readings
The display keeps displaying 9.9
Calibration value does not show on the
display (---)
The red warning light flashes
COMPLIANCE WITH EMC & ROHS DIRECTIVES
The ECTESTOC-3D-P DOSATRON SONDE 1R26-CTM-COS probe complies with the following
directives and provisions:
Requirements regarding protection set forth in Directive 2004/108/EC on "electromagnetic
compatibility".
Directive 2011/65/EU of the European Parliament regarding restrictions on the use of certain hazardous
substances in electrical and electronic equipment.
EU Declarations of Conformity are available upon request - please contact us.
©
©
DOSATRON INTERNATIONAL / 59
DOSATRON INTERNATIONAL / 59
Causes and solutions
- No batteries in the compartment.
- Batteries installed the wrong way round.
- Drained out batteries.
- The front panel pushbutton is broken.
- Probe suspended in the air.
- Probe wiring is cut.
- Poor fluid circulation.
- Check with a 1.413 mS conductivity
reference solution.
- Carry out the calibration process.
- Clean the 2 stainless steel electrodes with
fine grade emery cloth.
- Double-check the measurement with a
handheld meter.
- Short-circuit in probe wiring.
- Clean the 2 stainless steel electrodes with
fine grade emery cloth. They must be clean
and shiny.
- Probe wiring is cut.
- Short-circuit in probe wiring.
- The reference solution is too old or in bad
condition.
- The reference solution conductivity is not
1.413 mS.
- Replace the 2 1.5 V AA size batteries.

Reference Designation

REF.
Serial #
REF. : ............................................... N° Série : ............................................
EXEMPLE
D30
Dosatron
Type of
GL : Green Line (fertigation)
Dosage (% or ratio)
Probe
BP : integrated by-pass
V : Viscous Products ( > 400
cPs)
(> 400 cPs)
Dosing Seals:
AF = PH 7-14
VF = PH 1-7
K = strong acids (>15%)
Color :
P = White [PVDF]
Green
V =
[PP]
Other extensions
(consult us)
©
DOSATRON INTERNATIONAL / 60
GL
0.2
EC
BP
V
AF/VF
V
II

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Green d30

Tabla de contenido