EN
CN7 Connector for start-stop and internal/external radar and photocells
START
STOP
FOTO
RAD INT
RAD EXT
FOTO RALL
COM
CN8 Connettore alimentazione accessori 24V
+24V
-24V
CONNECTIONS DIAGRAM AND SIGNALING LEDS
CONNECTIONS DIAGRAM
INTERNAL RADAR
Sensor
Cable
connector
connector
EXTERNAL RADAR
Sensor
Cable
connector
connector
CONNECTIONS DIAGRAM 900PA014S
+
-
~ ~
12/24Vac
22
START input (Normally Open)
The START command determines the opening of the door, even in a locked state.
The command can be programmed with logical step by step or timed via the U parameter "OPEN
duration"
STOP input contact (Normally Closed)
The STOP command causes the immediate stopping of the door and, as long as it remains active,
any other commands are ignored.
Photocells input CONTACT (Normally Closed)
The FOTO command determines the reopening of the door being closed and, as long as it remains
active, does not allow for reclosing.
Internal radar INPUT CONTACT (Normally Open) Permits opening.
External radar INPUT CONTACT (Normally Open) Permits opening.
Photocells deceleration input CONTACT (Normally Closed)
The FOTO RALL command determines the slowdown of the door, both opening and closing; if the
contact is kept while opening, it does not allow for reclosing
Common inputs
Positive for powering radar and accessories
Negative for powering radar and accessories
900PA012
900PA012MW
Cable colors
Descrip radar
Grey
AC/DC 12 ~32V
Grey
AC/DC 12 ~32V
Yellow
N.O.
Yellow
N.O.
900PA012
900PA012MW
Cable colors
Descrip radar
Grey
AC/DC 12 ~32V
Grey
AC/DC 12 ~32V
Yellow
N.O.
Yellow
N.O.
RX1
TX1
START
STOP
FOTO
CLOSE
OPEN
RAD INT
RAD EXT
PHOTO RALL
INTERLOCK
HR942D
HR50
Connections
+24V
-24V
RAD INT
COM
HR942D
HR50
Connections
+24V
-24V
RAD EXT
COM
NC C N0
NO
NC
NC
NO
NO
NC
COM
900CT-PAE
NO
NC
NC
COM