4.2 - First start-up and programming 900CT-PAE
At start-up, the firmware version installed is displayed for 2 sec-
onds, then it switches to the operating mode (see step 4.5).
At first start-up of a new card, or after a reset of the parameters
(see step 6.2) the display shows "
learning operation (see step 4.3) is required.
Please note: Until the first learning operation has been completed,
4.3 - Learning Manoeuvres
At any time, by holding down the AS (P3) button for at least 2 sec-
onds until you hear a beep, the display shows the message
"
" you can command the learning operation.
Warning: the learning operation is recommended without safe-
ty devices connected (radar + photo...) in order to prevent false
starts or malfunctioning.
This manoeuvre begins with a start command from the control unit
AS
-
+
P2
P3
4.4 - Deceleration distance autoset manoeuvre
At any time, pressing and holding the AS button up to the
achievement of 2 beeps (after about 5 seconds)on the display
"
".
4.5 - Functions mode
Normally on the display at 5 seconds intervals the function modes
is visualizzed:
Bidirectional (the door is driven by both radars)
"
" -
A RAD INT or RAD EXT command determines the opening of the door,
which remains open for a time that can be modified by the user (see step
6.1 function U) and then closes.
A RAD INT or RAD EXT command sent during opening is ignored.
A RAD INT or RAD EXT command sent during closing reopens the door
immediately.
Free
"
" -
(the door does not receive any commands and can be
moved manually)
Placing the selector the door is free to be moved manually and ignores
any command.
This condition remains until the selector position is changed.
Exit
"
" -
(the door is driven only by the internal radar)
A RAD INT command determines the opening of the door, which remains
open for a time that can be modified by the user (see step 6.1 function U)
and then closes.
A RAD INT or RAD EXT command sent during opening is ignored.
A RAD INT command sent during closing reopens the door immediately.
Open
"
" -
(the door is open and radars are turned off)
Placing the selector on "Open" determines the opening of the door, which
remains open until the selector position is changed.
Lock
"
" -
(the door is closed and locked and radars are turned off)
Placing the selector on "Lock" determines the closing of the door and subse-
quent activation of the electric lock.
The door remains closed and locked, ignoring any command (except for
START and OPEN) until the selector position is changed.
Entrance
"
" -
(the gate is driven only by external radar) (*)
A RAD EXT command determines the opening of the door, which remains
open for a time that can be modified by the user (see step 6.1 function U)
and then closes.
A RAD INT or RAD EXT command sent during opening is ignored.
A RAD EXT command sent during closing reopens the door immediately.
24
", since, in this case, a
OK
M
P4
P5
START
all parameters will be reset to default at every start-up or reset.
The first opening and closing cycle after start-up is performed at a
reduced speed.
or radar and consists of six manoeuvres, THE FIRST OF WHICH IN
THE OPENING MODE, three openings and three closings, during
which the door learns its run and weight class (shown as C0, C1,
C2, C3, C4, C5, from lightest to heaviest).
Depending on the weight class, all the parameters of operation are
automatically set, but can be changed manually later (see step 6.1).
During learning mode, the slowdown distance for end of run are
also set, which are then fixed until a possible new learning.
Warning: Once learning is concluded reconnect the start and
safety devices.
The next two door manoeuvres will be used to re-learn the decel-
eration distance, if the conditions of the door (friction, etc..) were
changed from the previous learning.
Partial Opening
"
" -
A RAD INT or RAD EXT command determines the opening of the door; the
opening run is reduced to a percentage of the maximum run, that can be
modified by the user (see step 6.1 function B).
The door remains open for a time that can be modified by the user (see step
6.1 function U) and then closes.
A RAD INT or RAD EXT command sent during opening is ignored.
A RAD INT or RAD EXT command sent during closing reopens the door
immediately.
(*) The Input and Partial Opening modes share the sixth position of
the selector, which is set via the "T" parameter (see step 6.1).
When the is not installed (not detected at equipment start-up),
the mode of operation is Bidirectional.
In the event that the manual selector is no longer detected during
the operation
(because disconnected or because the connection is interrupted) the
mode of operation becomes Bidirectional, unless the functions Lock
or Free modes are active for safety reasons.
(*)