VENTILATION ADJUSTMENT
This function allows you to manage the ventilation speed.
It can be set to AUTO mode, which automatically adjusts the ventilation speed according to the power of the stove, or you can set
the ventilation speed according to the amount of hot air or to the desired noise level of the product.
To activate the function, press the
vent 1".
Press the
key and set the desired ventilation speed using the keys
To confi rm your choice, press the
SCREW LOADING (only if the stove is completely without pellets)
To load the screw, enter the MENU by pressing the key
loading" appears on the display.
Press the key
to confi rm, and then the key
This operation must only be carried out when the stove is off and completely cold.
Note: during this phase, the smoke extractor fan will remain on.
STAND-BY FUNCTION
In this mode, the stove will go off when the temperature of the environment is 0.5°C higher than that requested, after a set time of
10 minutes (which can be changed by the TAC during installation).
The message "GO STBY" will appear on the display, indicating the minutes remaining before switch-off.
This function is available in both 'AUTOMATIC' or 'MANUAL' mode and in the case of an external thermostat.
If the environmental temperature falls to 2°C below the set threshold, the stove will start up again (setting modifi able by the TAC
during installation).
To activate the function, press the key
until the message "M6 stand by" appears on the display, then confi rm by pressing the key
key
Press the key
to select "ON", then confi rm by pressing the key
To quit the menu "M6 stand by", press the key

SETTING THE DATE AND TIME

for about 2 second; the message "M1 set clock" will appear on the display; then confi rm by pressing the key
Press the key
The following data will appear in sequence: Day of the week, hour, minutes, day, month, year; these can be changed by pressing
the key
or the key
. To confi rm, press the key
To quit the menu "M1 set clock", press the key
EXTERNAL THERMOSTAT
This must be connected by the blue wire (optional code 640560) to the serial port positioned on the back of the stove; it must have
a clean, normally open contact (e.g. in the case of an environmental thermostat):
- Open contact = Environmental temperature reached
- Closed contact = Environmental temperature not reached
To select 'E-T' (external thermostat) mode, press the key
perature until the message 'E-T' (external thermostat) appears on the display (below 6°).
Note: When the stove is off, the external thermostat cannot switch the stove on or off.
If you want to switch the stove on or off outside the set time or outside the 'E-T' (external thermostat) setting, you must always
do so using the key
.
INSTRUCTIONS FOR USE
key for 2 seconds and press the
key.
for 2 seconds; then press the key
to activate the function.
for about 3 seconds; the message "M1 set clock" will appear on the display; press the
for about 6 seconds.
.
for about 6 seconds.
- 28
fkey until the display shows the message "M3 Adjust
and
.
.
(the LED will light up). Pressing the key
-
until the message "M5 Screw
.
will lower the tem-
.