Electrical installation

Connection data

Connection data
Terminal X107
)
Note!
The supply terminals (+/−) are protected against polarity reversal.
The supply status can be reported to the basic device via the error channel.
Further information can be obtained from the documentation of the basic
device.
Terminal data
Single core
1)
2 conductors
1)
Two conductors of the same cross−section with a twin wire end ferrule
36
Labelling
BD1
BD2
+ / −
SSP940X107
Conductor cross−section
2
[mm
]
0.25 ... 2.5
0.25 ... 1.5
l
Description
Connection of the motor holding brake
+ (Lenze: WH)
− (Lenze: BN)
E94AZHX0051: 24 V DC, max. 2.5 A
Observe correct polarity!
Supply voltage for the motor holding brake
(18 ... 30 V DC)
Observe correct polarity!
[AWG]
24 ... 12
0.5 ... 0.6
24 ... 16
Tightening torque
[Nm]
[lb−in]
4.4 ... 5.3
EDK94AZHX DE/EN/FR/ES/IT 5.0