FUEL
Be sure to use a strainer when filling the fuel tank. Dirt or sand in the fuel may cause trouble
in the fuel injection pump. ALWAY use No.2 diesel fuel, DO NOT use alternative fuels.
Alternative fuel may be inferior in quality and kerosene, which is very low in cetane rating,
adversely affects the engine. Be careful not to let the fuel tank become empty, as air can
enter the fuel system, which may require bleeding air from the fuel system.
Fuel is both toxic and flammable. Do not smoke while working with fuel. Do not use
near open flame. Start, store and refuel on level ground to prevent personal injury.
Do not run unit in an enclosed, non-ventilated area. Avoid prolonged breathing of
vapors and skin contact. Serious illness or loss of life could result.
Keep the vent hole in fuel tank cap open. If vent hole is plugged, pressure may build
up in tank, causing dangerous spraying of fuel when cap is removed. A vacuum may
also be created during operation, which could stop fuel flow.
uel Level
Check the fuel level when the
roller is parked on level ground
and the engine is off. Use the
sight tube located on the right
side of front frame to check fuel
level. The fuel cap is located on
the right side of the front frame
under the hood. The hood is
lockable and key is provided.
MOUNTING/DI MOUNTING THE MACHINE
The machine is fitted with steps and hand rails. Caution
should be used when mounting and dismounting the
O NOT remove or modify steps or hand rails.
machine.
Using the steps and hand rails, it is recommended to
mount and dismount facing the operators
O NOT jump from machine or
seat.
personal injury may occur.
COLD WEATHER TARTING
If the ambient temperature is below 23° F (-5° C) preheating times may be lengthened. The
preheat lamp goes off after 6 seconds. At low ambient temperatures, preheat for 10 seconds
and no more than 20 seconds. If engine fails to start, repeat preheat cycle.
WARNING
Handrail and step locations
Fuel Level Sight Gauge
Handrails
Step