INSTALLATION
Environment and Recycling
15.6 Wiring diagram
L2
L1
15 A Dual Pole
240 VAC
Circuit Breaker
Breaker Box
Outlet (Optional)
Wire Nuts
SB E Junction Box
The above wiring diagram shows the connection between the
circuit breaker and the SB E junction box.
16
|SB 300-400 E
Black
Black
Green/Yellow
SB E Junction Box
Black
Black
Wire Nuts
Green/Yellow
L2
Anode
Tank
Outer Casing
SB E Heating Element
The above wiring diagram shows the internal pre-wired con-
nection of the SB E.
16. Environment and Recycling
We ask you to help protect the environment. After use, dispose
of the various materials in accordance with national and local
regulations.
L1
Wiring Terminal
Safety Cutout
Thermostat
Heating Element
www.stiebel-eltron-usa.com