Settings with DIP2
(Lenze setting bold)
DIP2
Description
Rated motor
frequency /
reference speed
Configuration of
application
Control mode −
technology
application
Selection of DIP
switch /
potentiometer
assignment
EDK84DGDVBxxx4 DE/EN/FR/ES/IT 8.3
DIP switch / potentiometer assignment 1
50 Hz * / 1500 rpm
60 Hz * / 1800 rpm
87 Hz - / 2610 rpm
120 Hz * / 3600 rpm
Speed actuating drive (1000)
AC Drive Profile (1100)
Switch−off positioning (3000)
Reserved
9 (Local mode)
10 (terminals 0)
12 (terminals 2)
14 (terminals 11)
16 (terminals 16)
Reserved
41 (AS−Interface)
40 (MCI/CAN)
DIP switch / potentiometer
assignment 0
DIP switch / potentiometer
assignment 1
l
Settings
Switch
1
2
3
4
5
OFF OFF
ON OFF
OFF ON
ON
ON
OFF OFF
ON OFF
OFF ON
ON
ON
OFF OFF OFF
ON OFF OFF
OFF ON OFF
ON
OFF OFF ON
ON OFF ON
OFF ON
ON
5
6
7
8
ON OFF
ON
ON
ON
OFF
ON
87