HT Italia MPP300 Manual De Usuario página 16

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

32. To stop testing, press the GO/STOP key on instrument
SOLAR I-V and confirm with ENTER that you want to stop
recording
33. The display of SOLAR I-V will show the message "DATA
DOWNLOAD" to indicate that the data will be transferred to
the main unit during its various phases
34. After the automatic data transfer phase, the instrument:
 Do not show any results if do not exist on the PV
installation a "stable irradiance" condition more than the
minimum irradiance threshold (see see user's manual of
MASTER instrument) or all PRp values are not valid (PRp
> 1.15).
 Display the best performance values if during the
recording, the Irradiance values reached the "stable"
condition and its values were higher than the minimum
irradiance threshold (see user's manual of MASTER
instrument).
35. Press SAVE to save the results or ESC to exit the screen of
the results and go back to the initial screen
EN - 14
15/05/10 15:35:00
0 . 8 2
P R p
9 7 1
I r r
P n o m
3 . 5 0 0
4 5 . 1
T c
3 0 . 5
T e
P d c
3 . 1 2 5
P a c
2 . 9 6 0
n d c
0 . 8 6
0 . 9 5
n a c
A n a l y s i s R e s u l t
Select
M P P
MPP300
W / m 2
k W
° C
° C
k W
k W

Publicidad

Tabla de contenido
loading

Tabla de contenido