EN
STS 150 2.0
• Recommended load range for the system (in litres/day) at the specified tempe-
rature: 150 l/day at 45 °C.
• Thermal efficiency and solar fraction of the system in the recommended load ran-
ge. Data about long-term thermal efficiency and solar fraction determined from
the test for load volumes of 150 l/day for locations and conditions referenced in
standard EN12976:
Efficiency indicators for only-solar systems or solar preheating systems based
on annual demand volume of: 150 l/day
Location
(latitude)
[MJ]
Stockholm (59,6ºN)
8372
Würzburg (49,5ºN)
8029
Davos (46,8ºN)
9084
Athens (38,0ºN)
6239
STS 200 2.0
• Recommended load range for the system (in litres/day) at the specified tempe-
rature: 200 l/day at 45 °C.
• Thermal efficiency and solar fraction of the system in the recommended load ran-
ge. Data about long-term thermal efficiency and solar fraction determined from
the test for load volumes of 200 l/day for locations and conditions referenced in
standard EN12976:
Efficiency indicators for only-solar systems or solar preheating systems based
on annual demand volume of: 200 l/day
Location
(latitude)
[MJ]
Stockholm (59,6ºN)
11163
Würzburg (49,5ºN)
10705
Davos (46,8ºN)
12112
Athens (38,0ºN)
8319
STS 200 2.5
• Recommended load range for the system (in litres/day) at the specified tempe-
rature: 200 l/day at 45 °C.
• Thermal efficiency and solar fraction of the system in the recommended load ran-
ge. Data about long-term thermal efficiency and solar fraction determined from
the test for load volumes of 200 l/day for locations and conditions referenced in
standard EN12976:
Efficiency indicators for only-solar systems or solar preheating systems based
on annual demand volume of: 200 l/day
Location
(latitude)
[MJ]
Stockholm (59,6ºN)
11163
Würzburg (49,5ºN)
10705
Davos (46,8ºN)
12112
Athens (38,0ºN)
8319
Qd
QL
fsol
[MJ]
[%]
3454
41,3
3679
45,8
5073
55,8
4617
74,0
Qd
QL
fsol
[MJ]
[%]
3703
33,2
3996
37,3
5422
44,8
5418
65,1
Qd
QL
fsol
[MJ]
[%]
4324
38,7
4631
43,3
6408
52,9
5984
71,9
STS 300 2.0
• Recommended load range for the system (in litres/day) at the specified tempe-
rature: 300 l/day at 45 °C.
• Thermal efficiency and solar fraction of the system in the recommended load ran-
ge. Data about long-term thermal efficiency and solar fraction determined from
the test for load volumes of 300 l/day for locations and conditions referenced in
standard EN12976:
Efficiency indicators for only-solar systems or solar preheating systems based
on annual demand volume of: 300 l/day
Qpar
Location
[MJ]
(latitude)
---
Stockholm (59,6ºN)
---
Würzburg (49,5ºN)
---
Davos (46,8ºN)
---
Athens (38,0ºN)
INFORMATION
Overheating tests have been performed at thermosyphon systems. The results are
the following:
The total solar radiation in the plane of the solar collector during the
overheating prevention test was 101.0 MJ/m2, reaching an output maximum
temperature from reservoir tank of 101.1 °C.
When the system is in operation for several days without water removal and
the accumulated solar radiation in the plane of the solar collector is greater
than 101.0 MJ/m2, the system can be overheated. To prevent this, draw water
from the reservoir tank to a volume of approximately 3 times its content.
Qpar
[MJ]
---
---
---
---
Qpar
[MJ]
---
---
---
---
33
Qd
QL
fsol
[MJ]
[MJ]
[%]
16745
6836
40,8
16058
7325
45,6
18169
10244
56,4
12478
9302
74,6
10.0
Qpar
[MJ]
---
---
---
---