6 INSTALLATION
The stove can be installed with air distribution at
the front or channelled on the level of a chimney
with or without optional frame.
6.1 GENERATOR INSTALLATION ON A
CHIMNEY LEVEL.
In the event of installation in structures with marble
cladding or other materials, the stove has sliding
guides to assist with extracting the equipment for
attaching to the xing surface and for carrying out
inspections and checks on the mechanical and
electrical components.
6.1.1 POSITIONING THE GENERATOR WITHOUT
PEDESTAL
1. The lower part of the support base must be
unloaded to allow the air intake of the stove and
the cooling air inside the casing
2. Insert the Allen wrench (1) into the unlocked
unlocking seat; turn the locking lever in position
anti-clockwise (2) and pull the machine out until
the end of the run of the guides.
3. Remove the four bolts securing the machine,
two right side and two left side (Fig. 6.1.2).
4. Remove the four bolts securing the blade and
remove the blade (Fig. 6.1.3)
5. Lay the basement on the surface of the replace
(1), trace and drill 4 holes for xing (2) - use the
base itself as a template - then drill with a drill
bit. 6 mm (Fig. 6.1.4A).
1
Fig. 6.1.4A
INSTALLATION
2
Ø 6mm x 6
1
Fig. 6.1.4B
00 4776980 - 06/2018 - PN - Italy
Fig. 6.1.0
2
1
A
Fig. 6.1.1
Fig. 6.1.2
Fig. 6.1.3
3
Ø 6mm x 6
29