4.4.2) Cancellation of the positions or RDC function
To modify the previously memorised positions, they must firstly be cancelled and then the new positions programmed again.
In position "1" it can be changed without cancelling it (see table "A13").
Table "A6"
Cancellation of the intermediate position "I"
Press and hold down button n of a previously memorized transmitter until you hear a
1.
beep (after about 5 seconds)
Release and press again button n for another 5 seconds until 4 rapid beeps are heard
2.
Press buttons t and s together until 5 beeps are heard, indicating that the
3.
intermediate position has been cancelled
Table "A7"
Cancellation of positions "0" and "1"
Press and hold down button n of a previously memorized transmitter until you hear a
1.
beep (after about 5 seconds)
Release and press again button n for another 5 seconds until 4 rapid beeps are heard
2.
Press button t until 5 beeps signal that positions "0" and "1" have been cancelled
3.
WARNING: After positions "0" and "1" have been cancelled the awning will move with hold-to-run and a new position needs to be memo-
rised.
Note: the intermediate positions "I" and the RDC function that are programmed are not cancelled. If you wish to cancel everything (includ-
ing the codes of the transmitters), refer to table "A12".
Table "A8"
Cancellation of the torque reduction function (RDC)
Press and hold down button n of a previously memorized transmitter until you hear a
1.
beep (after about 5 seconds)
Release and press again button n for another 5 seconds until 4 rapid beeps are heard
2.
Press button n until 5 beeps signal that RDC function has been deactivated
3.
Note: Now the awning will close at full force
4.4.3) RDC level programming through the transmitter
The procedure allows the setting of the impact force which the motor will apply in the box closure phase (4 adjustable thresholds).
Table "A9"
RDC level programming
Press the s and n keys of the transmitter memorised in mode I at the same time
1.
until the motor makes 1 beep
2.
Within 5 seconds, with a frequency of 2 seconds, the raising button of the transmitter
to select the desired level:
- pressed once = level 1 (standard(*) reduction of the motor torque)
- pressed twice = level 2 (greater reduction of the motor torque)
- pressed 3 times = level 3 (much greater reduction of the motor torque)
- pressed 4 times = level 4 (high reduction of the motor torque)
3.
Wait for the motor to confirm the level just selected with a number beeps
(example: 3 beeps = level 3 selected)
Within 5 seconds from the last beep, confirm the level by briefly pressing the n key
4.
5.
If the procedure has been carried out correctly the motor will make 3 beeps