22.6 - TABELLA PARAMETRI DI PROGRAMMAZIONE
PARAMETER
VALUE
MODE
STAN
PRES
S.PRE
OROL
DIR
DX
SX
T.AP
0.0"-5.0'
T.CH
0.0"-5.0'
P.APP
0-100%
T.PRE
0.5"-10.0"
NO
T.PCH
0.5"-10.0"
NO
R.INV
0.1"-2.0"
NO
FREN
SI
NO
SEN.A
0.0A-9.9A
SEN.C
0.0A-9.9A
ST.AP
PAUS
CHIU
NO
ST.CH
STOP
APRE
ST.PA
CHIU
NO
PAUS
SUBMENU
DESCRIPTION
Working mode
Standard
Dead man
Mixed
Timer
Gate direction (the direction you see from
the inside)
The gate opens rightwards
The gate opens leftwards
Opening time
Closing time
Partial opening
Pre-blinking time before opening
Function disabled
Pre-blinking time before closing
Pre-flashing during closing equal to T.PRE
Delay at inversion
Function disabled
Brake function
Function enabled
Function disabled
Amperometric sensor level during opening
Amperometric sensor level during closing
Start during the opening phase
The gate stops and pauses
The gate immediately starts closing
The gate continues to open (the command is
ignored)
Start during the closing phase
The gate stops and the cycle is considered as
complete
The gate re-opens
Start during pause
The gate starts closing
This command is ignored
The pause time is reset
- 82 -
DEFAULT
CHAPTER
MEMO
18
STAN
DX
15"
16"
50%
13
1.0"
13
NO
9
0.5"
9
SI
12.1
0.0A
12.1
0.0A
16
PAUS
16
STOP
16
CHIU