Operation; Controller Overview - Oase FiltoMatic 3000 CWS Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

- GB -
Pos: 129 /Alle Produkte/Überschriften/H1 Bedienung @ 7\mod_1196625148604_121.doc @ 41443 @
8.

Operation

Pos: 130 /Filter/FiltoMatic CWS/Bedienung_FiltoMatic_CWS_Controller @ 13\mod_1259921096539_121.doc @ 84965 @
8.1

Controller overview

Displays on the controller
The display (C1) shows
the water temperature as standard.
automatically the water temperature again 2 seconds after the last key operation.
the cleaning programs if selected accordingly.
the saved settings when pressing a key.
the remaining operating life (h × 100) of the UVC lamp.
Displayed messages (C1)
"LA" flashes in an 8 sec. interval 1×: The UVC lamp was active for 7500 operating hours; remaining operating life: 500
operating hours
"LA" flashes in an 8 sec. interval 2×: The UVC lamp has operated for 8000 hours and should be replaced.
"PS" lights up in a 4 sec. interval: The dirty water pump has reached its max. running time and is blocked for 1.5 hours.
LED for dirty water pump (C2)
LED flashes green: Partial container drainage.
LED is lit green: complete container drainage.
LED is lit red: Pump blocked.
LED off: Pump not active.
LED for UVC clarifying unit (C3)
LED is lit blue: UVC clarifying unit is switched on.
The LED flashes in an 8 sec. interval blue: The UVC clarifying unit is integrated in the Automatic (AU) operating program.
LED off: UVC clarifying unit is switched off.
Note:
The integrated thermometer permanently measures the water temperature, thereby forming the reference value for the operating
programs.
The silicone cover protects the controller from soiling; it impairs neither the display reading nor the functionality of the keys. The
controller is water tight and can also be operated without the silicone cover.
Pos: 131 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1631 @
28
C1
Display
C2
LED displaying the dirty water
pump function
C3
LED displaying the UVC
function
C4
Key for manual dirty water
pump operation
C5
Key for setting a cleaning
program for the dirty water
pump
C6
Key for setting an operating
program for the UVC clarifying
unit

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Filtomatic 6000 cwsFiltomatic 12000 cwsFiltomatic

Tabla de contenido