6
Commissioning/Decommissioning
6.1
Commissioning
NOTICE
The pump/unit can be damaged if it runs dry!
Ensure that the pump/unit is always full of water. This also
applies to checking the rotation direction.
6.1.1
Fill the overhang counter swim unit with water
1.
Remove the cover.
NOTICE
Cover is clipped on. No tools are required to remove it.
Do not use force.
2.
Using the hand pump included (attached to the base plate)
ventilate the unit as follows.
– Attach the hose of the hand pump to the air drain valve on
the pump.
– Turn the air drain valve anti-clockwise to open.
– Pump until water flows out.
– Close the air drain valve clockwise and remove the hand
pump.
– Replace the hand pump in the attachment provided.
NOTICE
Close the air regulation valve to prevent any air being sucked
in.
3.
Replace the cover.
NOTICE
Ensure that the position switch on the cover is seated
correctly.
09|2018
Commissioning/Decommissioning
EN 25