Plumbing Installation - Continued
CAUTION: For trouble-free pump priming (up to 4 feet above the water line), first install a 6" long riser in the discharge
connection on top of the pump. Then install an elbow and lead the discharge line downward to the discharge connection at
the BaduJet super-sport II jet housing.
CAUTION: Allow at least 12 hours curing and bonding time. Insu cient curing and bonding time can result in leaks and
flooding.
CAUTION: Throughout the entire installation, make sure the plumbing connected to the BaduJet super-sport jet housing is
well supported. Unsupported plumbing WILL crack the jet housing.
CAUTION: DO NOT use the pump as a fixed point (support) for the plumbing.
CAUTION: When using 6" pipe, install 6" x 4" reducer bushings at the jet housing suction and discharge connections.
The 6" suction line should be run from the jet housing and remain under the water line to a point directly beneath the pump.
Install a 6" elbow at that point. Then run 4" pipe vertically up to the suction connection of the pump and finish with a 4"
elbow.
For optimal performance, use 4" plumbing when the
n
total distance between the pump and jet housing is
30 ft or less. The plumbing should be as direct and
free from turns or bends as possible because elbows
and other fittings can create large friction losses
and reduce the performance of the system.
The shortest length of pipe with the minimum
number of fittings possible should be used to
avoid any significant friction loss due to the pipe
and fittings. NOTE: Refer to Figure 2 for the BaduJet
super-sport head loss curve.
A maximum of seven (7) 90
n
with 30 ft of horizontal 4" pipe for the suction line
and 30 ft of horizontal 4" pipe for the discharge line
without negatively a ecting the performance of the
system.
If more elbows are required for the installation, 4" sweeps must be used in place of the elbows. When using sweeps
n
instead of elbows, a maximum of nine (9) 4" sweeps may be used with 30 ft of horizontal 4" pipe for the suction line
and 30 ft of horizontal 4" pipe for the discharge line without negatively a ecting the performance of the system.
If the pump cannot be located within 30 ft of the jet housing with the maximum number of 4" elbows or sweeps stated
n
above, then 6" plumbing must be used. For the suction line, use 6" plumbing and fittings from the connection at the jet
housing to a point directly beneath the pump. From that point, install a 6" elbow. Then run 4" pipe vertically up to the
suction connection of the pump and finish with a 4" elbow. For the discharge line, 6" plumbing should be installed from
the discharge connection of the pump all the way to the discharge connection of the jet housing.
CAUTION: The BaduJet super-sport system includes 30 ft of cable for the LED light and two 30 ft lengths of air tubing for
the air buttons. If the control box cannot be located within 30 ft of the jet housing, please contact the factory at (800) 223-
8538 or technical.usa@speck-pumps.com.
NOTE: Suction lines which are too long have significant disadvantages:
Higher resistance which results in less e cient priming and a higher risk of cavitation.
n
Longer priming time (up to 12 min).
n
Keep the suction and discharge lines as short and straight as possible.
n
If the pump is positioned further away, then the pipe dimensioning has to be adapted so that almost loss-free flowing
n
is ensured.
8
4" elbows may be used
o
35
30
25
20
15
10
5
0
0
50
100
150
U.S. Gallons Per Minute
Figure 2
BaduJet super-sport II Head Loss Curve
200
250
300
350
400
450