Plumbing - continued
Figure 3
Sample BaduJet super-sport II Installation (Self-Priming)
Valves (Optional)
Discharge Line
Control
Service
Box
Disconnect
NOTE: Valves are recommended when pump is installed
below water level (flooded suction applications).
4"
Pneumatic
NOTE: To avoid stress on the housing, the jet housing
Hose
and 2 to 3 inches of plumbing/conduit stub out may be
encased in gunite or concrete.
Pump
Vertical
Discharge Connection
(Discharge Line)
Vertical Suction Line
Horizontal
4"
Water Level
4"
Discharge Connection
(Discharge Line)
Check Valve (Optional)
(Below Water Level)
1/2" Conduit
~12"
(Air Regulator)
4"
4"
3/4" Conduit
(Pneumatic Hoses & Light Cables)
Horizontal Suction Line
max. 30 feet with 4" pipe
Figure 4
BaduJet Dimensional Drawing
WATER LEVEL
WATER LEVEL
DISCHARGE
CENTER LINE
4" SLIP CONNECTION
11.5"
SUCTION
4" SLIP CONNECTION
6.7"
1.5"
9.4"
20.65"
Jet Housing Installation - New Concrete or Gunite Construction
CAUTION: All necessary screws and bolts included with the BaduJet super-sport are stainless steel. ALL screw threads and
threaded inserts are METRIC! ONLY METRIC bolts and nuts may be used! All screws should be HAND TIGHT. DO NOT use
drills or pneumatic tools. DO NOT over tighten!
9