Step 2 - Replace The Orifices And Venturis - Thermador SNLPKITF Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Remove the hexagon shaped cap from the regulator
making sure not to dislodge the gasket on the cap or the
spring inside the regulator.
.
Grasp the plastic button stem (stem) firmly and pull it
forcefully from the metal cap. The stem snaps snugly into
an indent in the cap and may require a strong pull to
remove.
After removing the stem from the cap, rotate the stem 180°
so the button end of the stem is away from the cap and the
letters "LP" on the stem are upside down when the cap is
set flat on its head. Snap the stem back in place in this
position inserting it into the indent in the metal cap.The
stem should snap into place.
Natural
Gas
Important - Attach the metallic sticker (included with this
conversion kit) to the bottom of the appliance as shown,
placing it near the appliance data plate (shows model
number and information about the appliance). This sticker
provides notice that the appliance has been converted for
use with LP gas
.
bottom of cooktop
plastic
button stem
spring
gasket
LP
Gas
Step 2 - Replace the Orifices and
Venturis
1. Remove the grates and burner caps.
2. Remove the venturis using a 20 mm socket.
3. Set the NG (natural gas) venturis aside and save for
later use if needed.
Note:
Do not remove the ignitor from the unit.
4. Remove the orifices.
Note:
The orifices require a 7 mm socket driver for
removal/replacement. The driver will need to be
inserted approximately 2 1/2" (64 mm) into the
burner cavity to reach the orifice.
Hint:
To reduce the chance of the orifice being dropped
from the socket driver, add a piece of foam tape or
adhesive tape inside the socket.
a) Trim a small piece of the foam tape provided with
this kit (about 1/4" x 1/2"; 6mm x 12mm).
b) Fit this so the tape wraps against one side of the
socket so it stays in place.
c) When pressing the socket driver onto the orifice,
the tape will fit to the orifice and help prevent the
orifice from falling out of the socket during
extraction.
Save the NG orifices in case there is need later to restore
the appliance to use natural gas again.
Installation Procedure
venturi
ignitor
4