8
Care and maintenance
If required, clean the DMSP−... / MAS−... with water or soap suds (max. 60 °C).
S
9

Dismantling and repairs

If there are signs of wear as listed in the chapter on operation:
Replace the DMSP−... / MAS−... completely.
S
The safety requirements concerning the connection between the contractible
membrane and the connecting flange do not at present permit repairs to this
unit.
Before dismantling the DMSP−... / MAS−...:
Exhaust the complete system and the product.
S
10
Accessories
Designation
Old adapter
New adapter
Flexocoupling
Rod clevis
Coupling item
*)
Please observe the assignment of accessories and DMSP−... / MAS−... types in
accordance with catalogue specifications. If an MAS−10−...−K with force locking is
replaced by an MAS−10−... without force locking, the existing adapter (with long
fastening thread) will damage the connecting thread of the MAS−10−... .
**)
Only for MAS−...−K/O−...
Fig. 14
22
*)
Type
**)
MXAC−...
**)
MXAD−...
FK−...
SG..−...
KS..−...
Festo DMSP−... / MAS−... 0501c − English