DMSP−... / MAS−...
11
Eliminating faults
Fault
Work load is not lifted
The required force is
not reached
Clearly audible blowing
(only with MAS−...−K)
Heavy leakage
DMSP−... / MAS−...
does not achieve the
desired speed
desired speed
Fig. 15
12
Technical specifications
DMSP−... / MAS−...
Design
Mounting position
Medium
Permitted operating pressure
Festo DMSP−... / MAS−... 0501c − English
Possible cause
Insufficient operating
pressure
Max. permitted force
exceeded
Operating pressure too
high
Loading too high
Muscle fibre worn
Insufficient air volume
Mass or counteracting
force too high
10−...
Fibre−reinforced contractible membrane
As desired
Compressed air lubricated or non−lubricated
(other media on request)
0...8 bar
Remedy
Increase operating pressure to max.
permitted value (see Technical
specifications)
Use a larger DMSP−... / MAS−...
Reduce operating pressure
Reduce load
Replace DMSP−... / MAS−...
Increase connection cross sections,
switch volumes in series
Select larger DMSP−... / MAS−...
20−...
0...6 bar
40−...
23