mENu
The automatic closure is enabled or disabled
TCA
On: enabled automatic closure
Off: disabled automatic closure
The multi-flat function is enabled or disabled.
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the impulse of the tran-
IbL
smitter have no effect in the opening phase.
Off: disabled multi-flat function.
The operating mode of "P.P. Push button" and of the transmitter are selected.
PP
On: Operation : OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Forewarning flashing light enabled or disabled.
On: enabled forewarning flashing light. The flashing light is activated 3 s before the starting of
PRE
the motor.
Off: disabled forewarning flashing light.
The lock function in the closing phase is enabled or disabled.
See paragraph "Operating mode with Enabled/Disabled encoder".
blc
On: Lock function is enabled.
Off: Lock function is disabled.
During the TCA time, the blinker is enabled or disabled.
ltca
On: Activated blinker.
Off: De-activated blinker.
The pick-up function with ENC:OFF logics is activated or deactivated.
On: the function is enabled. The first two seconds of operation are carried out at maximum
spn
torque.
With ENC:ON logics, pick-up is automatically adjusted by the control unit.
The Operator function is enabled or disabled.
On: Operator function enabled.
htr
During operation, the OPEN/CLOSE push-buttons must be kept pressed.
Off: Automatic/semiautomatic operation.
During the TCA phase, the PP and PED controls are enabled or disabled.
IBCA
On: PP and PED controls are disabled.
Off: PP and PED controls are enabled.
The Encoder is enabled or disabled.
On: Enabled encoder.
Off: Disabled encoder (to be used with ZED series motors that are not equipped with built-in
ENC
Encoder).
NB: The Encoder can be possibly reset (from OFF to ON). A new self-calibration procedure is
required (AUTO menu).
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
CVAR
Off: Receiver enabled for rolling-code and programmable code transmitters (self-learning and
Dip Switch).
The operating mode of the PHOT input is selected.
On: PHOT input is activated in both opening and closing.
In the opening phase: when the contact is opened, the motor stops. When the photocell is
released, the motor restarts with an opening movement.
PHTo
In the closing phase: when the contact is opened, the motor stops. When the photocell is
released, the motor inverts its movement direction (opens).
Off: PHOT input is activated only in the closing phase.
In the closing phase: when the contact is opened, the motor stops and the movement direc-
tion is immediately reversed (opens).
The remote storage of the radio transmitter codes is enabled or disabled (see par. REMOTE
LEARNING).
rem
On: Enabled remote storage
Off: Disabled remote storage.
LOGIC (LOG)
FuNCTioN
oN-oFF-
mEmo
(default)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)
(OFF)
15