Troubleshooting

If you experience problems while setting up your system, refer to the
troubleshooting information in the following table. If the problem persists, see "How
to Get Technical Assistance" on page en-37.
Problem
System does not power on
when the front panel standby
switch is pressed.
System does not power on
when the keyboard Standby
key is pressed.
System powers on, but
monitor does not.
System and monitor power
on, but no video displays on
the monitor screen.
Keyboard or mouse does not
respond to actions.
During boot procedure,
system gives the error
message,
Warning: timed out
waiting for NIS to
come up.
en-36
Solution
1) Verify the system power cord is connected to the system and a wall
outlet.
2) Verify there is power to the wall outlet.
3) Verify that voltage selector is set to the correct voltage.
1) Verify the keyboard cable is attached to the system keyboard connector.
2) Verify the system power cord is connected to the system and a wall
outlet.
3) Verify there is power to the wall outlet.
4) Verify that voltage selector is set to the correct voltage.
1) Verify the monitor power cord is connected to a wall outlet.
2) Verify there is power to the wall outlet.
1) Verify the monitor cable is attached to the system motherboard or
optional graphics card.
1) Verify the mouse cable is attached to the keyboard.
2) Verify the keyboard cable is attached to the system keyboard connector.
1) Verify the Ethernet cable is connected at the system and the wall.
2) Verify with your system administrator that the network is operational.