DISPLAY
Adjustment of sensitivity of the electronic clutch and of motor power.
A1
Minimum motor power, more sensitive to obstacle
A2
Medium-low motor power, medium-high sensitivity to obstacles
A3
Medium-high motor power, medium-low sensitivity to obstacles
A4
High motor power, low sensitivity to obstacles
Automatic Reclosure: this function enables or disables automatic gate reclosing
c0
Disabled
c1
Enabled
Operation of OPEN A command: this function determines the behaviour of the OPEN A (total opening) push-button.
d0
Opens / Closes / Opens
d1
Opens / Stops / Closes / Stops
Condominium function: if this function is enabled while the gate is being opened, the start command is disabled.
E0
Disabled
E1
Enabled
Courtesy light/ Flashing lamp: with this parameter, you can select the type of output from the LAMP - LAMP terminals,
selecting from flashing lamp and courtesy light. IMPORTANT: Maximum load of terminals: 24 Vdc 15W max.
G0
Flashing lamp
G1
Courtesy light (active for about 2 minutes)
Slow-down point percentage: this parameter is used to set the length of the slowed down section, selecting it from
the four fixed values
H1
10% of maximum memory-stored opening
H2
20% of maximum memory-stored opening
H3
30% of maximum memory-stored opening
H4
40% of maximum memory-stored opening
Speed during slowed-down phase: this parameter is used to set motor speed during the slowed down phase, selecting
it from the two values
i0
High
i1
Low
Operation with encoder or encoder+travel limit device: with this function, you can choose the type of automated
operation. When operating only with the encoder, at the end of the closing manoeuvre the control unit commands
brief motion in order to facilitate a possible release operation.
L0
Operation with encoder only
L1
Operation with encoder and travel limit device
Pre-flashing at closure: if this function is activated before the closing phase, the flashing lamp pre-flashes to indicate
that the gate is about to move. Pre-flashing time is about 1.5 seconds and cannot be modified.
n0
Pre-flashing excluded
n1
Pre-flashing ON
Immediate closure: if this function is activated, when the gate is open during a pause, and therefore with Automatic,
Automatic step-by-step or condominium logics, when one transits in front of the photocells active during closure or during
opening and closure, the gate closes immediately, without waiting for the programmed pause time to elapse.
o0
Immediate closure disabled
o1
Immediate closure enabled
Immediate closure/timer command: this function enables you to command immediate closure of the gate or to close it
with the OPEN A total opening command. This function is only active in combination with function logics with automatic
closure of the gate (Automatic, Step-by-step Automatic and Condo).
Immediate closure: when the gate is open during a pause given with the OPEN A command, the gate
P0
begins the closing manoeuvre without waiting for pause time to elapse.
Timer Function: when the gate is open during a pause, with a single impulse of the OPEN A command, the
control unit restarts counting the pause time before reclosing. If you keep pressing the OPEN A command,
P1
the pause time count stops and the gate stays open until the OPEN A command is active. When you release
the command, the gate recloses when pause time has elapsed.
Soft Block Function: this function is used to activate brief braking of the gate before gate motion is stopped
r0
Function not active: leaf stops immediately
r1
Function active: gate brakes briefly before it stops
DESCRIPTION