4
Vertical Convection Heaters
Specifications
Description
Fuel Type
Input (Btuh/kW)
Inlet gas supply pressure
acceptable at the gas con-
nection of the heater (see
Footnote 1)
Burner manifold pressure
(see Footnote 1)
Fuel consumption per hour
(see Footnote 2)
Dimensions (Inches/cm)
LxWxH
Minimum safe distances
from nearest combustible
materials (Feet/Meters)
Footnote 1: Gas pressures:
Footnote 2: Fuel consumption:
Footnote 3:
Owner's Manual • Workman & Norseman
320
Propane Gas
MAX.
200,000 / 58.6
MIN.
N/A
MAX.
23 / 158.6
MIN.
23 / 158.6
23 / 158.6
MAX.
9.28 / 4.21
MIN.
N/A
18x13x24/
46x33x61
TOP
5 ft. 10 in. / 1.77
SIDES
BELOW
O
PROPANE
US: 6/1.83 Canada: 10/3.05
Models 320, 341, and CV225: expressed in PSIG/kPa.
Model CV100: expressed in Inches of Water Column / kPa
Models 320, 341, and CV225: expressed in pounds/kilograms per hour
Model CV100: expressed in cubic feet / cubic meters per hour.
DO NOT place this heater on any combustible material
Model
341
CV225
Propane Gas
Propane Gas
250,000 / 73.3
225,000 / 65.9
N/A
45,000 / 13.2
23 / 158.6
10.2 / 70.3
23 / 158.6
10.2 / 70.3
23 / 158.6
10.0 / 68.9
11.6 / 5.26
10.44 / 4.73
N/A
2.08 / 0.94
18x13x24/
17x15x26/
46x33x61
43x38x66
8.0/2.43
5 ft. 10 in. / 1.77
4.0 / 1.2
See Footnote 3
CV100
Natural Gas
100,000 / 29.3
N/A
13.5 / 3.36
7.0 / 1.74
5.1 / 1.27
100 / 2.83
N/A
16.5x15x25/
42x38x64
5.0 / 1.52
3.0 / .91
O
O
N/A