1. Lift Location: Use architects plan when available
to locate lift. Fig. 1a shows dimensions of a typical bay
layout.
Lift Height: See Fig. 2 for overall lift height of each
specific lift model. Add 1" min. to overall height to
lowest obstruction.
Overhead Assembly
SPO12 (500/700) &
SPO12 (5A0/7A0)
13'-8"
[4166mm]
STD. Top
Overhead
Assembly
EH-1 14'-8" [4470mm]
Tie Bar & Spacers -use
EH-2 15'-8" [4775mm]
(2) 3/8"-16NCx2-1/2"
EH-3 16'-8" [5080mm]
Carriage Bolts and
(SPO12LC
11'-8"
[3556mm])
front and (2) in the back
Note: See Pg. 3 for Hummer (5W0/7W0 Series) Lifts.
WARNING
DO NOT install this lift in a pit or
depression due to fire or explosion risks.
2. Latch Cable Guides: Install the latch cable conduit guide
brackets to column extensions with (1) 1/4"-20NC x 1" HHCS
and 1/4"-20NC Flanged Locknuts, Fig. 3. HHCS should go
through hole nearest the edge as shown, Fig. 3.
Mounting
Bracket
3/8"-16NCx3/4" HHCS
& Flanged Locknut
Flanged Locknuts
Use (2) 3/8"-16NCx1"
Carriage Bolts and
Flanged Locknuts in
Fig. 2
Overhead Mounting Bracket: Install Mounting Brackets
to column extensions as shown, Fig. 2.
3. Column Extensions: While column is on the ground,
install column extensions using (4) 3/8"-16NC x 1" lg.
Carriage Bolt and Flanged Locknut, Fig. 3 & Fig. 1b. Use (2)
3/8"-16NC x 2-1/2" lg. Carriage Bolt and Flanged Locknut to
attach the tie bar and the column extension together at the
column's uppermost holes, Fig. 3. The tie bar is positioned
on the outside of the column extension. Adjust the column
extensions plumb.
4. Lift Setting: Position columns in bay using dimensions
shown in Fig. 1a. Place column with power unit mounting
bracket on vehicle passenger side of lift. Both column base
plate backs must be square on center line of lift. Notches
are cut into each base plate to indicate center line of lift.
Use appropriate equipment to raise carriage to first latch
position. Be sure locking latch is securely engaged.
IMPORTANT: All star washers are to be mounted on the
right side column to ensure grounding of overhead limit
switch. Star washers are not needed when mounting to left
side column. Notice the column extension mounting, Fig. 3
and overhead limit switch mounting as well in Fig. 3 & Fig. 6.
5
Fig. 3