Anchor:
Min
Min Edge
Concrete
Distance
Thickness
Hilti Kwik
4-1/4"
3-3/8"
Bolt III (3/4" x
(108mm)
(86mm)
5-1/2")
Hilti HY200
5-1/4"
1-3/4"
(with HAS
(134mm)
(45mm)
threaded rod)
"Automotive Lifts - Safety Requirements for Construction, Testing, and Validation" ANSI/ALI ALCTV-2011,
and the lift owner is responsible for all charges related to any additional anchoring requirements as
specified by local codes. Contact customer service for further information at: 800.640.5438
Anchor
Shims (1/2"(12.7mm) Max.)
Drill holes using 3/4" carbide
tipped masonry drill bit per
ANSI B212.15-1994 (R2000).
Construction dust collected
per OSHA 29 CFR 1926.1153.
Fig. 4
12K 2-Post Lift Anchor Installation Reference Guide
Min Anchor
Installation Anchor
Embedment
Torque Ft-lbs
3-1/4" (83mm) 110
3-1/2" (89mm) 100 / less than 3-3/4"
edge distance use
Torque Value of 30
FT/LBS
*The supplied concrete fasteners meet the criteria of the American National Standard
Flat Washer
Run nut down just below impact
section of bolt. Drive anchor
into hole until nut and washer
contact base.
Min Concrete PSI
Strength - For All
Standards
3000
3000
Nut
Fig. 5
NOTE: If more than 2 horse shoe shims are used at any of the
column anchor bolts, pack non-shrink grout under the unsupported
area of the column base. Insure shims are held tightly between the
baseplate and floor after torquing anchors.
7
Tighten nut with Torque
wrench to 110 ft.-lbs
(149 Nm).
Concrete pad
Maintenance
Size If Concrete
Torque
Does Not Meet
Values
Requirements
4'x4'x6"
65
4'x4'x6"
N/A
.
SEISMIC
Varies by
location consult
with your
structural engineer
and manufacturer's
representative.