14.2 PASSENGER PROTECTION DEVICE INPUT AND SUPPLY
The Input is activated if put at GND.
Terminal
+24V
IPD
GND
N.C.
14.3 OUTPUTS
The outputs are relais where the 3 connections of the contacts are feed to the terminals.
(O1 to O4: COMMON = COM, normally open contact = NO, normally close contact = NC)
Terminal
O1
O2
O3
O4
Technical data:
- Voltage:
230 VAC / 30 VDC
- Power:
max 2A continuous load
Sujeto a cambios sin previo aviso
Symbol
Name of the terminal
PH+
+24V
REV
PHOTO CELL
PH-
GND
L
Symbol
Name of the terminal
OPEN END
CLOSE END
REV
REOPEN
POS
Position
EXCELLENCE IN COMPONENTS
Explanation
+24V DC supply for photo cell or curtain of
light (max. 150mA)
Input for Photo Cell or curtain of light, light
barrier or other passenger protection device
Ground for supply of photo cell or curtain of
light (light barrier)
Can be used as terminal for light barrier
Explanation
The open end output indicates the fully open
position of door panels.
The close end output indicates the fully closed
position of door panels
The Reopen output indicates if a reopen
request, coming from photo cell or close force
limiter is pending or an automatic re-open is
done.
This output is set when the door is opened
wider than a certain position (Position trigger
point can be adjusted by WPT normally deacti-
vated).