Wittur Eco BUS Manual De Instrucciones página 36

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3411.32.0100 ed.0
GB
Pag.34.78
20.4.2.3
'F1': Reset to default
Reset to Default?
YES/NO F8 Back
By pressing the 'YES' button all the factory adjusted parameters are cleared and overwritten by
default values.
Before resetting the door electronic to default values the two items 11.3, clause 3 and 4 must be fol-
lowed (manual closing of door panels without opening of coupler!).
After the "Reset to Default" is done, continue the start-up procedure like described in item 11.3
clause 6 to 10.
20.4.3 'F1': Door Movement
F1 Open Speed
F2 Close Speed
F3 Nudging Speed
F4 Next
This menu allows you to watch/modify values described in the following chapters by pressing the corre-
sponding function key.
See chapter 20.4.2.1 how to enter values.
All these variables are stored in the EEPROM. Speed values for speed setting 1-3 are calculated from val-
ues of speed setting 4 by multiplying with fix constants (see chapter 11).
20.4.3.1
'F1 Open speed' - Open speed
Top speed for open movement; speed setting 4.
20.4.3.2
'F2 Close speed' - Close speed
Top speed for close movement; speed setting 4.
20.4.3.3
'F3 Nudging speed' - Close speed for nudging
Top speed for close movement with nudging command; speed setting 4.
Sujeto a cambios sin previo aviso
F8 Back
EXCELLENCE IN COMPONENTS
Subject to change without notice!

Hide quick links:

Publicidad

Capítulos

Tabla de contenido
loading

Productos relacionados para Wittur Eco BUS

Tabla de contenido