IT GB
boiler parameters
Press the Menu button.
Turn the knob and select menu 2 "Boiler
Parameters"; press the confi rmation but-
ton. Press the confi rmation button again to
select parameter 21 "Access code". Turn the
knob to enter the access code and press the
confi rmation button.
Turn the knob and select parameter:
- 22 General Settings
press the confi rmation button and turn the
knob to select one of the following options:
220 Slow ignition level
221 Zones Anti-freeze Temp. (room)
222 Fan modulation exclusion
223 Under-fl oor heating or RT2
224 Mechanical timer fi tted
225 Delayed heating start time
226 Flue gas/air pipe length
227 Temperature adjustment device
228 Boiler version
Press the confi rmation button and turn the
knob to change the value or setting, then
press the confi rmation button.
Press the exit button to return to the previ-
ous screen.
- 23 Heating - part 1
press the confi rmation button and turn the
knob to select one of the following options:
230 Max. absolute heating power level
231 Max. adjustable heating power level
232 Max. domestic hot water rpm percent-
age
233 Min. rpm percentage
234 Max. heating rpm percentage
235 Heating delay type
236 Set delayed ignition
237 Heating post-circulation
238 Circulation pump operation
239 Circulation pump modulation T delta
Press the confi rmation button and turn the
knob to change the value or setting, then
press the confi rmation button.
56
General
220
Soft ignition
221
Zone frost T
222
Fan modulati
225
CH Start Del
228 Boiler versi
Back
Select
Boiler version
44
5.0
1
0
0
Enter