Table Of Error Codes - Ariston CLIMA MANAGER Instrucciones Operativas

Ocultar thumbs Ver también para CLIMA MANAGER:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

IT GB

table of error codes

Display
Description
PRIMARY CIRCUIT
1 01
Overheating
1 02
Heating pressure sensor short-circuited or circuit open
1 03
Circulation or water present:
Flow T gradient > 7°C/sec for 3 times
1 04
Circulation or water present: Flow T gradient > 15°C/sec or return T gradient 15°C/sec
1 05
Circulation or water present: Flow T - Return T > 55°C for 3 times
1 06
Circulation or water present: Return T > Flow T + 10°C for 3 times
1 07
Circulation or water present: Return T > Flow T + 30°C
1 08
No water in the primary circuit (P<Pmin) (no semi-automatic fi lling)
1 09
High primary circuit pressure (P>3 bar)
1 10
Heating fl ow sensor (NTC1) short circuit or circuit open
1 11
No water in the primary circuit (P<Pmin) (yes semi-automatic fi lling)
1 12
Return Probe Damaged
1 14
Outdoor Sensor Damaged
1 16
Under-fl oor heating thermostat open
1 18
Primary Probes Test Fail
1 P1
1 P2
Flow Check Failed
1 P3
1 P4
Filling Needed / Push Filling Key
1 P5
Filling Not Completed
1 P6
1 P7
Too many fi lling attempts
1 P8
Too many fi lling attempts
DOMESTIC HOT WATER CIRCUIT
2 01
DHW Probe Damaged
2 02
Storage Lower Probe Damaged
2 03
Tank Probe Damaged
2 04
Solar Collector Probe Damaged
2 05
DHW In Probe Open Circuit
2 07
Solar Coll Max Temp
2 08
Solar Coll Frost Prot
2 09
Tank Overheat
ELECTRONIC CONTROL UNIT
3 01
Display EEPR error
3 02
GP-GIU comm error
80
Restore
Reset
No Reset
Reset
Reset
Reset
Reset
Reset
No Reset
No Reset
No Reset
No Reset
No Reset
No Reset
No Reset
on /off
on /off
No Reset
No Reset
No Reset
No Reset
No Reset
No Reset
No Reset
No Reset
No Reset