Solar Heating System & Indirect Cylinder - Ariston CLIMA MANAGER Instrucciones Operativas

Ocultar thumbs Ver también para CLIMA MANAGER:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

IT GB
solar heating system & indirect cylinder
Press the Menu button.
Turn the knob and select menu 3 "Solar
heating system & Indirect cylinder"; press
the confi rmation button.
Turn the knob and select:
30 General settings, press the confi rmation
button and turn the knob to select param-
eter 300 Set storage tank temperature;
press the confi rmation button and turn the
knob to change the value, then press the
confi rmation button.
Press the exit button to return to the previ-
ous screen.
Turn the knob and select:
31 "Access code"; press the confi rm button.
Turn the knob to enter the access code and
press the confi rmation button.
Caution: these parameters are only enabled
with the solar control P.C.B.
Turn the knob and select:
320 Anti-Legionnaire's disease
321 Solar confi guration
322 Enable Electrical Valve\Mixer
323 Collector T delta for Pump start-up
324 Collector T delta for Pump Stop
325 Collector min. T for Pump Start
326 Ram at collector
327 Recooling function
328 Delta at setpoint Gas storage
329 Collector Anti-freeze T
Press the confi rmation button and turn the
knob to change the value or setting, then
press the confi rmation button.
Press the exit button to return to the previ-
ous screen.
58
Param Code: 300
Storage Setpoint T
40
Back
Validate

Publicidad

Tabla de contenido
loading

Tabla de contenido