Fireplace Installation
the red wire (L2) from the unit
to the neutral wire from the
power supply.
!
NOTE: The unit can also
be installed so that the heater is
disabled. To install the unit with
No Heat DO NOT connect the
red wire (L2) to the neutral wire.
Add a wire connector to the end
and leave it disconnected from
everything.
!
NOTE: The unit can also be
installed using an external Heat
Disconnect Switch. This can be
installed by adding a single pole
single throw wall switch between
the red wire (L2) on the unit.
• Attach the grounding wire to
the cover with the provided
grounding screw. Place wire
in-between screw and lock
washer and tighten (Figure 4).
• Reposition the electrical cover
brackets over the wires and
connectors and attach to fire-
place chassis using the screw
removed in step 1 and step 3.
• Ensure that the voltage selec-
tor switch is set at the correct
voltage. (See Installation -
Voltage Selector Switch)
10
For 240V Installations
Use three conductor, non-metallic
sheath cable with ground wire
(4 wires total) for the incoming
power supply on fireplace inserts.
CAUTION: Use the appropri-
ate wire to meet local and
national electrical codes for
rated power consumption.
• Connect the black wire (L1)
from the unit to the L1 wire
from the power supply.
• Connect the red wire (L2)
from the unit to the L2 wire
from the power supply.
!
NOTE: The unit can also
be installed so that the heater is
disabled. To install the unit with
No Heat DO NOT connect the
red wire (L2) to the neutral wire.
Add a wire connector to the end
and leave it disconnected from
everything.
!
NOTE: The unit can also be
installed using an external Heat
Disconnect Switch. This can be
installed by adding a single pole
single throw wall switch between
the red wire (L2) on the unit.
• Connect the white wire (N)
from the unit to the neutral
wire from the power supply.