Front Glass Installation - Dimplex BLF74 Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Fireplace Installation
opening of 73 in. (185.4 cm)
wide x 18 ½ in. (47 cm) high
(Figure 8).
!
NOTE: It is recommended
that the bottom of the unit not be
mounted higher than 40 in.
(102 cm) from the ground to main-
tain an optimized viewing angle of
the flame.
WARNING: Do not attempt
to wire your own new outlets or
circuits. To reduce the risk of fire,
electric shock or injury to persons,
always use a licensed electrician.
WARNING: Ensure that the On/
Off Switch is set to the Off position
(refer to Operation section) and that
the circuit on which the fireplace is
to be installed has the power cut off
at the service panel until installation
is complete.
2. Lift fireplace and insert into
opening. The fireplace's
mounting trim should be flush
against the wall (Figure 8).
3. Use the supplied bubble level
to level the fireplace within the
framing, adjust as required.
4. Drive four supplied mounting
screws through the four mount-
ing holes located on the inside
surface of the fireplace chassis,
into wall studs (Figure 9).
14
5. Refer to Front Glass Installa-
tion section for final installation
procedures.

Front Glass Installation

1. Evenly distribute supplied
glass rock on the front tray of
the fireplace (Figure 10).
2. Carefully mount front glass
assembly so that the front
glass hooks hang on the front
glass mounts on the fireplace
(Figure 10).
3. Use the supplied four Phillips
sheet metal screws to fasten
the glass assembly tabs to the
fireplace (Figure 11).
www.dimplex.com

Publicidad

Tabla de contenido
loading

Tabla de contenido