SMA SUNNY TRIPOWER STORAGE 60 Instrucciones De Instalación Y Reglaje página 37

Ocultar thumbs Ver también para SUNNY TRIPOWER STORAGE 60:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

SMA Solar Technology AG
ID
Status
message
2056
Fallback
completed
Table 4.3 System-related event
Internal Events
ID
Status
message
201–
208
209,
210
211
Low fan
speed
213–
215
216–
218
219–
221
225–
240,
275
241,
242,
245,
249
248
252–
254
Installation Manual
Description
The inverter has switched back
to normal operation after
having been in the fallback
mode due to a communication
disturbance with the SMA
Inverter Manager.
Description
The internal temperature of the
inverter is too high.
Voltage in DC link is too high.
Fan speed is too low.
Internal error. Voltage
measured before and after the
relay differs too much.
Current measured on AC side
is too high.
Internal error. Voltage
measured before and after the
relay differs too much.
Failure in memory/EEPROM.
Internal communications fault.
Internal CPU error.
Current measured on AC side
is too high.
Measure
Measure
Verify that no objects or dust are on
top of the inverter and make sure
that the air ducts are clear and not
blocked.
If the event persists, reset the
inverter by disconnecting DC and
AC. If the event is repeated, check
the maximum DC voltage using the
display to see if it is above the limits.
Check whether the inverter fan is
blocked.
Contact the service.
Contact the service.
Contact the service.
Restart the inverter. If the event
persists, call Service.
Restart the inverter. If the event
persists, call Service.
Restart the inverter. If the event
persists, call Service.
If the event repeats, call Service.
4  Service
DNO
SMA
Service
Line
-
-
DNO
SMA
DC
Service
Line
-
x
-
x
-
x
-
x
-
x
-
x
-
x
-
x
-
x
-
x
STPS60-IA-xx-12
DC
-
-
-
-
-
-
-
-
-
-
-
37

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Stps60-10

Tabla de contenido