Fig. 8
Connecting the water tube
Cut the water tube to size at the dotted white
line as shown in
Fig.
8a.
Slide the hose clip (supplied) on to the water
tube
Fig.
8b.
Remove the 2 x Phillips screws and unclip the
solenoid from the backplate
Fig.
8b.
Attach the water hose to the solenoid
Clip the solenoid back on to the backplate
and fasten the 2 x screws
Fig.
8d.
Tighten the hose clip and ensure the
solenoid cable is correctly positioned in the
retaining channel.
Fig. 9
Connecting the electricity supply
Route the electricity supply to the backplate
using approved flexible or solid conduit
and fittings. Ensure the power cable is long
enough to connect to the terminal block
mounted in the back plate.
Route the cable into the backplate and tighten
the cable gland.
Strip the cable to a suitable length and
US
secure the live and neutral wires into the
corresponding terminal blocks as shown in
USES
Fig.
9. Ensure the correct positioning of the
AR
cables before proceeding.
CL
GT
MX
PA
308
Fig. 10
Re-assemble electrical cover
Fix the electrics cover and secure with
the 6 x fixings supplied ensuring no wires
are trapped.
Fig. 11
Connecting the mixed water supply
Ensure water feed has been completely
Fig.
8c.
flushed of debris, copper filings etc. prior to
connecting to the backplate. Failure to do
so may damage the solenoid valve resulting
in it not closing properly, creating a a
dripping tap.
Connect the isolated, mixed water supply to
the backplate.
Turn on the water.
Inspect for leaks at the main water supply inlet
and the water tube connection to the tap.
Also check for leaks at the
solenoid connection.
Fig. 12
Switching power on
Switch on power to the machine.
CALIBRATION CYCLE: Once installed,
the tap will go through a 30 second
calibration cycle.
Place hand under sensor on tap to activate
water flow.
Fig.
12a.
Check for leaks as per
Fig.
11.
Secure the water pipe cover onto the
backplate using the 2 x fixings provided.
Fig.
12b.
Fig. 13
Assembling the motor bucket
Hook the motor to the top of the electrics
cover. Swing it downwards so it clicks into
place as shown. Push in securely
Fig.
13a.
OPTIONAL: A screw is supplied to secure the
red release button and prevent unwanted
removal of the motor bucket.
Test the unit for correct operation.
Securing the motor bucket to the backplate
(optional).
To remove the filter, gently use a screwdriver
to release the tab on the filter as shown
Fig.
13b.
Secure the motor bucket to the backplate
using the security screw supplied
Fig.
13c.
Re-connect the filter ensuring that it clicks into
place
Fig.
13d.