Test Installation; Troubleshooting - Dyson Airblade 1 Guia De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 310
Test
installation
Test the hand dryer for normal operation:
– Place your hands beneath the centre of
the tap and water will flow automatically
for as long as the hands remain in place.
– Place your hands to either side of the
centre tap to activate the hand dryer,
creating sheets of air to scrape water from
your hands.
– Move your hands backwards and forwards
slowly through the air, turning them over
so both back and front are exposed to
the airflow.

Troubleshooting

Hand dryer fails to start:
– Check fuse/circuit breaker is working
and that the power and water supply
are connected.
– Ensure the cleaning cap is removed
and that the sensors are clean
and unobstructed.
– Turn the unit off and on.
Hand dryer turns itself on and
off erratically:
– Turn the unit off and on.
– Ensure there is no plug in the sink and
remove if plug is present.
– Ensure sensors are clean.
– Check that the sensor cable from the tap
is securely connected.
Hand dryer sometimes cuts out in use:
– Turn the unit off and on.
– Ensure sensors are clean.
– Check the air inlets are clean and free
of dust. If the air inlets are dusty simply
remove dust.
– Ensure that the air inlets are free from
obstructions and have sufficient clearance.
The dry time has increased:
– Inspect the air inlets for dust and remove.
– Inspect filter and change if required.
– Ensure that the hose is securely attached
to the base of the tap and no leaks
are present.
The airflow is running hotter than usual:
– Inspect the air inlets for dust and remove.
– Inspect filter and change if required.
– Ensure that the hose is securely attached
to the base of the tap and no leaks
are present.
Air is continuously running:
– Check for any object in the sink and
remove if necessary.
– Ensure sensors are clean and free from
any obstructions.
– Inspect filter and change if required.
– Ensure that the hose is securely attached
to the base of the tap and no leaks
are present.
There is no air running:
– Turn the unit off and on.
– Check fuse/circuit breaker is working and
that the power is connected.
– Ensure sensors are clean.
– Ensure that the air hose is securely
attached to the base of the tap and no
leaks are present.
– Check that the sensor cable from the tap
is securely connected.
Water is continuously coming from the tap:
– Ensure sensors are clean and free from
any obstructions.
There is no water coming from the tap:
– Ensure that the power and water supplies
are turned on and that the isolation valve
is open.
– Ensure that the aerator is free from debris,
remove and clean/replace if necessary.
The water coming from the tap is overly hot
or cold:
– Check the blender valve is set to the
desired temperature.
Contact Dyson Customer Care for further
support and information or online at
www.dysoncanada.ca
CA
CAFR
43

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Airblade 1aAirblade wash+dry 1a

Tabla de contenido