Devices Connection
• To activate the power output move the overload thermal
protector lever (A) upwards.
• After the generator is started connect the devices
needed (B) into the connection panel.
CAUTION
When connecting more than one
device, connect and start those using a higher current first.
CAUTION
Double check the devices do not exceed
the generator rated power longer than 30 minutes and to
never exceed the maximum load output.
• To assure the generator can supply enough energy and
run the power devices to be connected please follow the
next steps to estimate the necessary watts and not exceed
the generator capacity:
1. Choose the power devices to be connected
simultaneously.
2. The amount of energy necessary to run all the devices
is the sum of the watts rated power of those devices. The
values of the addition shall not go over the generator
capacity.
3. While starting, the power devices will produce large
amounts of current. The devices shall start one by one.
They shall not start simultaneously.
CAUTION
To learn the rated power output, consult
the table in the right side of the page as a reference or the
technical specifications of each of the devices' instructions.
Digital Voltmeter
• The generator is built with a digital voltmeter that will
turn on when the overload thermal protector is turned
On.
• The voltmeter is used to monitor the following
magnitudes:
1. Maximum voltage generated by the device
2. Frequency of operation
3. Time of operation per session
4. Total operation time
• To change between voltmeter magnitudes, press button (C).
Overload
CAUTION
• If an important overload is present, the overload thermal protector will shut down. It is a possibility that a
marginal overload will not shut down the thermal protector but will shorten the generator useful life.
CAUTION
• If the thermal protector shuts down due to an overloaded circuit, reduce the circuit electric load and wait a
couple of minutes before re-starting the thermal protector.
• Each 127 V double - polarized socket is built with a 20 A thermal protector.
10
ENGLISH
Start Up
A
Reference
in watts
Appliances
Power Tools
U-220
( Voltage - 220 V )
F-60
( Frequency - 60 Hz )
001,0
1 hour
009,8
9,8 hours
Device
Power (W)
Light Saving Lamp
Refrigerator
Fan
Tablet
Laptop
Washing Machine
Computer
Electric Range
Air conditioner
Water Pump
Drill Hammer
9" Grinder
Reverse Welder
B
Rated
5 - 50
50
50
120
120
250
400
1 000
1 600
800
1 000
2 400
3 600
C