Fuel And Oil; Fuel Supply - Truper GEN-100X Manual Del Usario

Generador de corriente eléctrica
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Oil Supply
• Set the generator onto a flat and leveled surface.
• Turn and pull the oil supply cap (A).
• Use 4-stroke engine oil. Using SAE 10W/30 for general use
under any temperature. Other viscosities can be used when
the average temperature in your locality is within the range
indicated in the following table.
10 W - 30
-20
0
20
• To check the oil level remove the oil dipstick (B) in the
generator and clean with a clean cloth.
• The oil tank has an approximate capacity of 0.39 gallons.
Pour oil gradually and wait a couple of minutes so the oil
can settle into the engine.
• Insert the oil dipstick into the orifice. See if it shows the
maximum oil level.
• If the level is below the minimum, add oil until it reaches
the maximum level on the dipstick.
• Set the dipstick back into the orifice and tighten.
CAUTION
• Checking oil level regularly is
recommended.
• When the oil tank is filled to the right level indicated in
the dipstick, set back the cap (A) and tighten to prevent
oil leaks.
CAUTION
• Do not exceed the maximum oil level.
The muffler may expel too much smoke when the engine
starts.
• Check oil level before each use. If
CAUTION
necessary, add oil up to the limits in the dipstick.
CAUTION
• Replace oil after each 20-hours
operation. It may be necessary to change oil more
frequently when dust or dirt are present.

Fuel Supply

• Set the generator onto a flat and leveled surface.
• Clean and dry the area around the fuel cap.
• Remove the fuel cap (C).
• Using a funnel slowly fill up the fuel tank up
to the lower part of the tank's neck. Do not fill
in excess to allow fuel expansion and prevent
spills (D).
• Wipe clean any fuel spilled.
• Cover the cap turning the cap until hearing a
click.
• Clean any fuel spills before starting the engine.
8
ENGLISH
10 W - 40
40
60
80
100 °F

Fuel and Oil

Operating at High Altitude
• The air-fuel mix in a standard carburetor is rich in fuel at
high altitudes. Performance will be low and fuel
consumption will be high.
• Performance while operating at high altitudes could
improve if the carburetor is regulated adjusting the main
bolt. The generator is set to operate in altitudes 6000 ft
above sea level. If the generator is not working efficiently
go to a
carry out the required modification to the carburetor.
• Although the carburetor has the adequate injection, the
engine potency will decrease approximately 3,5 % per each
1000 ft increment above sea level. Potency will decrease if
no modifications are carried out to the carburetor.
WARNING
• If the generator is operated in an
altitude inadequate to the carburetor setting it could
perform poorly, overheat and the engine will be severely
damaged due to the excessive air mix in the fuel.
C
Authorized Service Center to
B
Maximum
oil level
Minimum
oil level
D
A

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

14359