Descargar Imprimir esta página

DIVERSITECH ClearVue Mini Manual De Instrucciones

Ocultar thumbs Ver también para ClearVue Mini:

Publicidad

Enlaces rápidos

ClearVue Mini
TM
System Installation

Publicidad

loading

Resumen de contenidos para DIVERSITECH ClearVue Mini

  • Página 1 ClearVue Mini System Installation...
  • Página 2 Introduction ClearVue Mini features Unpacking System Installation Safety, Location Consideration and Mounting Safety Switch Electrical Connection Inlet and Outlet Tubing Connections Operation LED Indications Maintenance Troubleshooting 10 Troubleshooting Guide 12 Technical Data...
  • Página 3 CLEARVUE MINI uses patent pending water sensing technology to detect condensate so that there are no more stuck floats! CLEARVUE MINI also features a see-through tank to give the service tech and homeowner a clear view of water, blockage, and buildup in the tank. This clear tank allows for quick troubleshooting due to normal buildup caused by daily condensate generation.
  • Página 4 Variable Lift & Speed Variable lift determines how hard the CLEARVUE MINI needs to pump in a given installation. The variable lift in CLEARVUE MINI assures that the pump is only pumping as hard as needed to lift the condensate water to the height needed.
  • Página 5 Installation, Location Consideration, and Mounting The CLEARVUE MINI may be installed in several different ways depending on the unit and location. These options include: 1. Above ceiling 2. Inside lineset cover 3. Inside evaporator 4. Behind evaporator mounting bracket in space behind drywall...
  • Página 6: Safety Switch

    Once the switch is triggered, the red LED will illuminate to alert the user. The CLEARVUE MINI safety switch can be wired following these diagrams that are generic to the manufacturer. Should your manufacturer require other wiring, please follow their instructions or consult them for help.
  • Página 7: Electrical Connection

    Electrical Connection Supply voltage and frequency must match what is shown on the pump nameplate. Source voltages lower than rated supply can reduce performance and cause the pump to overheat. Wire the pump into a properly grounded receptacle capable of providing power that exceeds the requirements listed on the pump nameplate.
  • Página 8 Inlet and Outlet Tubing Connections The pump is equipped with barb-type fittings. The supplied .5cm / 3/16” tubing is recommended for connections between the pump. The inlet tank tubing is connected to the discharge line of the mini-split cassette head unit.
  • Página 9: Pump Operation

    Pump Operation Apply power by properly wiring the pump. Check for green LED illumination which indicates that the power is available. Test the pump operation and safety switch by manually filling the tank. Be sure that the red ALARM LED lights when the pump has reached an overflow condition and will properly shut off the system.
  • Página 12 3190890 Motor Operated Water Pump *Performs best at 3’. Pump must be primed in order to provide maximum suction lift. Manufactured by DiversiTech Corporation 6650 Sugarloaf Parkway DOC32106 Duluth, GA 30097 ©2012 DiversiTech Corporation www.diversitech.com Version No. 2, August 2012...