Speedrite 15 J Unigizer Manual De Instrucciones página 2

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 12
Key to symbols on the energizer
Fence earth terminal. Connect the Fence earth terminal to the
energizer earth system.
Fence earth monitor terminal. Connect the Fence earth monitor
terminal to a separate earth rod. See
Fence low energy terminal. For use in areas where a limit of 1.5 J
output energy is desirable (e.g. where there is likely to be
unsupervised children who will be unaware of the dangers of
Lowering the energy output
electric fencing), see
Connect the Fence low energy terminal to the fence.
Fence high energy terminal. Connect the Fence high energy
terminal to the main farm fence.
Risk of electric shock! This energizer should be opened or repaired
only by qualified personnel.
Read full instructions before use.
This symbol on the product or its packaging indicates that this
product must not be disposed of with other waste. Instead, it is
your responsibility to dispose of your waste equipment by handing
it over to a designated collection point for the recycling of waste
electrical and electronic equipment. The separate collection and
recycling of your waste equipment at the time of disposal will help
conserve natural resources and ensure that it is recycled in a
manner that protects human health and the environment. For more
information about where you can drop off your waste equipment
for recycling, please contact your local city recycling office or the
dealer from whom you purchased the product.
The energizer has a double-insulated construction.
Energizers marked with this symbol are time delayed electric fence
energizers with a delay time of 15 seconds.
Warning!
- Switch the energizer off before installation or performing any work
on the fence.
- Read all the safety considerations carefully. See
on page 9.
- Check your installation to ensure that it complies with all local safety
regulations.
- When the temperature is below 5 °C, the energizer must be located
in a shelter and any cables attached, in particular, must not be
handled.
- Use only the mains/line power adaptor or battery leads supplied with
this energizer or a genuine replacement part.
- The power input socket on the back of the energizer is for 12 V DC
only.
Notes:
-
This product has been designed for use with electric animal fences.
-
Keep these instructions in a handy location.
2
Earth monitoring
on page 5.
on page 7.
Safety considerations
Installation
Read all of the safety instructions in this manual and any relevant
government, regional and local safety standards before installing the
energizer.
Selecting a site for the installation
Follow these guidelines when selecting a site for your installation.
Select a site where:
a good earth can be obtained
the energizer earth system will be at least 10 m (33') from other
earth systems (e.g. telephone, mains power or the earth system of
another energizer)
children and animals cannot interfere with the installation
Make sure the energizer is installed:
adjacent to the electric fence
preferably in the middle of the electric fence system
close to a mains/line power outlet (if using a mains/line supply to
power the energizer)
at least 1 m (3') away from and not directly above the battery (if
using a battery to power the energizer)
If your installation is outdoors, also make sure that it is:
on firm ground away from flooding
inside a protective fence, if required.
Using the power adaptor and battery leads
The energizer is supplied with a power adaptor (for connection to
mains/line power) and a set of battery leads (for connection to a battery).
Before connecting a power adaptor or battery leads, ensure the energizer's
selector switch is set to Off
To use the power adaptor:
1
Connect the power adaptor to the Power input socket on the rear of
the energizer.
2
Connect the power adaptor to a suitable mains/line power socket,
ensuring there is 25 mm (1") of clear space around the power
adaptor.
To remove the power adaptor:
1
Disconnect the power adaptor from the mains/line power.
2
Pull on the white connector to remove the power adaptor plug from
the Power input socket on the rear of the energizer.
To use the battery leads:
1
Insert the battery lead into the Power input socket on the rear of the
energizer.
2
Connect the energizer to the battery using the battery leads supplied.
Attach the red clip to the positive (+) terminal of the battery, and the
black clip to its negative (-) terminal.
Note:
If the energizer is to be used as part of a permanent outdoor
installation such as a solar installation, the battery lead clips should be
replaced by permanent battery connectors.
To remove the battery leads:
1
Remove the clips from the battery terminals.
2
Hold the battery lead by the rubber sleeve at the end of the wire. Pull
firmly to remove the connector from the Power input socket on the
rear of the energizer.
.

Publicidad

Tabla de contenido
loading

Productos relacionados para Speedrite 15 J Unigizer

Tabla de contenido