TRIPPING THE CIRCUIT BREAKERS
TRIPPING THE CIRCUIT BREAKERS
TRIPPING THE CIRCUIT BREAKERS
TRIPPING THE CIRCUIT BREAKERS
TRIPPING THE CIRCUIT BREAKERS
The circuit breakers protect electrical circuits and motors from damage due to overload conditions. If a circuit breaker trips,
try to determine the cause, then press the button to reset the breaker.
If the vacuum circuit breaker trips, check for foam in the recovery tank. If foam is present, it may enter and overload the vacuum
motor.
If the brush circuit breaker trips, look for debris wrapped around the brush drive shafts.
If any of the circuit breakers trip repeatedly, contact your Advance Dealer for service.
POOR W
POOR W
POOR WA A A A A TER PICK-UP
POOR W
POOR W
TER PICK-UP
TER PICK-UP
TER PICK-UP
TER PICK-UP
1 1 1 1 1
Recovery tank full, vacuum float shut-off closed.
2 2 2 2 2
Drain plug not sealing on drain hose.
3 3 3 3 3
Plugged vacuum system (squeegee and hoses).
4 4 4 4 4
Disconnected, damaged, or kinked vacuum hoses.
5 5 5 5 5
Incorrectly adjusted squeegee.
SQUEEGEE STREAKS
SQUEEGEE STREAKS
SQUEEGEE STREAKS
SQUEEGEE STREAKS
SQUEEGEE STREAKS
1 1 1 1 1
Debris under the squeegee blade
2 2 2 2 2
Worn, nicked or torn squeegee blades
3 3 3 3 3
Incorrectly adjusted squeegee
SWIRL MARKS
SWIRL MARKS
SWIRL MARKS
SWIRL MARKS
SWIRL MARKS
1 1 1 1 1
Running the machine with dry brushes or pads (no cleaning solution)
2 2 2 2 2
Using incorrect brushes (or pads) for the application
29 29 29 29 29 - - - - - FORM NO. 56041352 - Convertamatic