Removing Case From Shipping Skid
CAUTION: Do not lift case from bottom front panel, damage will occur.
Move the case as near as possible to the final location before removing it from the
shipping skid. Remove blocking from front and sides attached to pallet and remove shipping
brackets from rear of case attached to pallet.
Removing Packaging Material
Remove bubble wrap and packing material for all shelves, etc. If it is
necessary to remove tape residue from various materials, use cleaning
compounds recommended in the cleaning section of this manual.
Leveling the Case
The case must be level for proper drainage of defrost water.
Check the level of the case along the front rail and along the inner tub floor below the
display deck. Shim under the case frame as needed to level the case. It is
recommended that the leveled case be sealed to the counter with an NSF Listed
Sealant.
Cleaning for Initial Setup
For initial setup, clean the case as outlined in the "Weekly Cleaning" section of the
"CLEANING INSTRUCTIONS" chapter of this manual.
Lights
Standard LED Top Light
The case comes with one standard LED top light which is internally wired to the power
source. The light switch is located in the top ceiling behind the air discharge duct.
Standard LED Shelf Lights
Two LED shelf lights are furnished, make certain that the shelf light cords are
completely inserted into the sockets in the end of the light or arcing may result, causing
damage to the plugs and sockets. Plugs must be orientated correctly ( note divot in plug
and socket ) or lights will not work.
The power supply used on this case allows removal of one or more shelf lights without
affecting the remaining lights.
When plugging or unplugging light cords, turn the light switch to the "OFF" position.
Refrigerated Self-Serve Merchandiser (High Profile)