RECEPTACLES
120 Volt AC, 20 Amp Duplex
Receptacle
Use only high quality, well-insulated,
extension cords
with the generator's
120 Volt electrical receptacles.
4-Wire Cord Set
240V -_
Each receptacle is protected against overload by a
single 20 Amp push-to-reset circuit breaker. Use each
receptacle to operate 120 Volt AC, single phase 60 Hz
electrical loads requiring up to 2,400 watts (2.4 kW) at
20 Amps of current.
_
CAUTION!
Although each receptacle is rated
for 120 Volts at 20 Amps (2,400 watts or
2.4 kW), the generator is rated for a total of
6,000 watts. Powering loads that exceed the
wattage capacity of the generator can damage it
or cause serious injuries. See "Don't Overload
the Generator" on page 11.
Check the ratings of all extension cords before you
use them. Extension cord sets used should be rated
for 125 Volt AC loads at 20 Amps or greater for most
electrical devices. Some devices, however, may not
require this type of extension cord. Check the owner's
manuals of those devices for the manufacturer's
recommendations.
Keep extension cords as short as possible, preferably
less than 15 feet long, to prevent voltage drop and
possible overheating of wires.
120/240
Volt AC, 30 Amp Receptacle
This is a full capacity receptacle; it can take the
generator's full rated output from this sole
NEMA L14-30 outlet. The outlet is protected by two
30 Amp push-to-reset
circuit breakers.
A NEMA L14-30 plug is required to use with the
240 Volt receptacle. Connect a suitable 4-wire cord set
to the plug and to the desired load. The cord set
should be rated for 250 Volt AC loads at 30 Amps (or
greater).
120 Volt AC, 30 Amp Receptacle
Use a NEMA L5-30 plug with this receptacle. Connect
a 3-wire cord set rated for 125 Volt AC loads at
30 Amps to the plug.
3-Wire Cord Set
C
i_ i
Neutral
120V
Hot
-7L7 Ground
NEMA L5-30
(Green)
Use this receptacle to operate 120 Volt AC, 60 Hz,
single phase loads requiring up to 3,600 watts
(3.6 kW) of power at 30 Amps. The outlet is protected
by a 30 Amp push-to-reset circuit breaker.