Descargar Imprimir esta página

Radio Control; Technical Data - Sirius SCISIU24TC Istrucciones De Uso

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31
WORKING
Mod. Module standard version (Fig. 8)
A: Light switch on/off
B: Motor switch on/off (1st rate level)
C: 2nd rate level switch
D: 3rd rate level switch
E: Warning gem
Mod. SIM (Fig. 9)
A: Light switch on/off
B: Motor switch on/off (1st rate level)
C: 2nd rate level switch
D: 3rd rate level switch
E: 10 - minutes timer
F: Warning gem
Mod. SIL-Module luxury version (Fig. 10)
A: Light switch on/off
B: Motor switch on/off (1st rate level)
C: 2nd rate level switch
D: 3rd rate level switch
E: 4th rate level switch
F: 10 - minutes timer
Mod. SIL TC - Touch Control version (Dis.16)
A: Light switch On/Off
B: Reduce speed
C: Luminous telltale
D: Incrase speed
E: 10 - minute timer
The touch control key allows the function de-
sired by touching the relative key. The lumi-
nous telltales (C) positioned at the center of
the keyboard indicate the suction speed set.
In case of an active timer, the upper telltale
(C) flashes.
If the push button console malfunctions, re-
move the grease filters and press the red but-
ton inside the appliance twice.
If the electrical power supply to the product
SILTC is cut, 15 seconds are needed for self-
diagnostics after the functions are restored.
In the meanwhile, its operation may be in-
correct.
RC001
R
C
ADIO
ONTROL
Radio control used for the remote operation
of ducted cooker hoods.
TECHNICAL DATA
- Alkaline battery powered: 12V mod. 27A
- Operating frequency: 433.92 Mhz
- Combinations: 32.768
- Max. consumption: 25 mA
- Operating temperature: -20 ÷ + 55 °C
- Dimensions: 130x45x15 mm.
OPERATING DESCRIPTION
The transmitter is equipped with 5 buttons
for cooker hood management, as specified
below:
: Light ON/OFF command.
: Motor ON (speed level 1) / OFF command.
: Reduce speed.
: Increase speed.
: 10-minute timer.
INITIAL OPERATING CONDITION
The manufacturer supplies the radio control
unit ready to be used with codes preset in the
Factory
OPERATION MODE
Standard configuration:
Standard configuration requires all "cooker
hoods – radio control - system" to be pro-
vided with the same transmission code. In
the event two cooker hoods – radio control
system are installed in the same room or ne-
arby, each system may affect the operation of
the another. Therefore, the code of one radio
control system must be changed.
19

Publicidad

loading

Este manual también es adecuado para:

Scpsutc9290iScim406iScim406nScpsutc97nScim405