11. Technical Data

Height measurements
Distance Accuracy
(Standard Deviation)
Range
Optical - Shortest
focusing distance
Measuring time single
measure (Electronic)
Circular Bubble
Compensator
Power Supply
Technical Data
Standard deviation per km double run (ISO 17123-2):
• Electronic measurement with Sprinter aluminum barcode staff: 2.0mm
• Optical measurement with standard aluminum E-scale/Numeral staff: 2.5mm
• Standard Deviation for single staff reading: 0.6 mm (electronic) and 1.2 mm
(optical) at 30m
10 mm for D<= 10 m
Distance in m x 0.001 for D>10 m
Distance measuring range for electronic measurements with standard
aluminum barcode staff: 2 m to 100 m.
50 cm
Typically 3 seconds and less in normal daylight condition; needs longer
measuring time in uniform dim light condition (20 lux).
Circular Bubble Sensitivity: 10'/2 mm
Magnet damped pendulum compensator with electronic range monitoring
• Tilt Warning Range (Electronically): ± 10'
• Compensator range (Mechanically): ± 10'
• Setting accuracy: 0.8" max. (Standard Deviation)
• Magnetic field sensitivity: < 10"
(Line-of-sight difference in horizontal constant magnetic field at a field
strength of up 5 Gauss)
Internal battery