Safe Use Instructions – Emerson FloBoss 103 Flow Manager
Part D301194X012
February 2018
Specifications
POWER
External power charging input: 8-28 v dc, reverse
polarity protection.
Input current: 5 mA nominal. 9.5 mA at 100% duty
cycle.
Enclosure
Housing and cap: die-cast aluminum alloy with
iridite plating and paint. Stainless steel (CF8M)
version available.
ENVIRONMENTAL
Temperature (operating):
–40C to +75C.
–20C to +75C (LCD display).
Temperature (storage, non-operating):
–50C to +85C.
Relative Humidity: 5-95% non-condensing.
WEIGHT
6.58 kg (aluminum): 12.1 kg (SST).
DVS SENSOR (OPTIONAL)
DIFFERENTIAL PRESSURE INPUT
Range: 0 - 62.2 kPa.
Reference Accuracy: 0.075% or 0.10% of URL
(includes linearity, hysteresis, and repeatability effects).
STATIC PRESSURE INPUT
Range: Either Absolute or Gauge:
0 – 5516 kPa.
0 – 25,000 kPa.
Reference Accuracy: 0.075% or 0.10% of URL
(includes linearity, hysteresis, and repeatability effects).
Stability: 0.1% of upper range limit for 12 months.
2
Specifications
APPROVALS
ATEX Version (Flameproof & Type n)
Evaluated per Approval standards:
(Flameproof)
EN 60079-0 (2012)
EN 60079-1 (2007)
IEC 60529
Certified by LCIE as Model W40116.
ATEX Cert LCIE 03ATEX6221 X
ATEX Cert LCIE 13ATEX1033 X
Product Markings for Hazardous Locations:
Ex d IIB T5 Gb (-40°C ≤ T
Ex nA IIB T3 Gc (-40°C ≤ T
II 2/3 G.
0081
IECEx Version (Flameproof and Type n)
Evaluated per Approval standards:
IEC 60079-0 (2011)
IEC 60079-1 (2007)
IEC 60079-15 (2010)
IEC 60529
Certified by CSA as Model W40149.
IEC Cert IECEx LCI 08.0039 (Flameproof)
IEC Cert IECEx LCI 08.0015 (Type n)
Product Markings for Hazardous Locations:
Ex d IIB T5 Gb (-40°C ≤ T
Ex nA IIC T3 Gc (-40°C ≤ T
IECEx Version (Type n Only)
Evaluated per Approval standards:
IEC 60079-0 (2011)
IEC 60079-15 (2010)
IEC 60529
Certified by CSA as Model W40150.
IEC Cert IECEx LCI 08.0015 (Type n)
Product Markings for Hazardous Locations:
Ex nA IIC T3 Gc (-40°C ≤ T
The following tools are required for installation,
maintenance, and troubleshooting:
Personal computer running Microsoft
▪
Windows 8.1, or Windows 10 and Emerson Field Tools
configuration software (providing ROCLINK™ 800
configuration software).
Phillips (cross-head) screwdriver.
▪
▪
Flat-head screwdriver.
Hex socket wrench (M4).
▪
1. You receive the FloBoss 103 in a box. Remove it from
the box.
www.Emerson.com/RemoteAutomation
(Type n)
EN 60079-0 (2012)
EN 60079-15 (2010)
IEC 60529
≤ +75°C), IP66.
amb
≤ +75°C), IP66.
amb
≤ +75°C), IP66
amb
≤ +75°C), IP66
amb
≤ +75°C), IP66
amb
®
Windows
®