Operating Instructions
Read Head CET-AX with Guard Locking and Guard Lock Monitoring
Figure 11: Connection of suitable EMC performance
Read head/order number
CET.-AX-...
Table 1:
Installation positions
Order No./item
095735
CET1-AX-LRA-00-50X-SA
100399
CET1-AX-LDA-00-50X-SE
104051
1)
CET1-AX-LRA-00-50X-SF
104062
CET1-AX-LRA-00-50L-SA
102161
CET1-AX-LRA-00-50F-SA
103750
CET1-AX-LDA-00-50F-SA
111917
CET1-AX-LRA-00-50X-SA-C2333-111917
111918
CET1-AX-LRA-00-50F-SA-C2333-111918
106039
CET2-AX-LRA-00-50X-SA
102988
CET1-AX-LRA-00-50X-SC
103444
CET1-AX-LDA-00-50X-SC
109932
CET2-AX-LRA-00-50X-SC
096327
CET-A-BWK-50X
073456
M5x16/V100
1)
Plug connector can be rotated by 360°.
Table 2:
Ordering table for read heads and actuators
H11 H12
24V 0V
CE S
Data Cable
(H11/H12)
TS T
OU T
13
14
Evaluation unit/order number
CES-AZ-.ES-...
1)
Actuator, locking force 6,500 N (incl. safety screws)
Safety screws M5 x 16 for actuator (replacement), packaging unit: 100 ea.
13
Shield (SH1)
To PLC/Power Supply
SH
ER R
GN D
23
24
Installation position
Head upward
Head downward or horizontal
75 mm
75 mm
75 mm
Achievable category and PL according to
EN ISO 13849-1
3 / PL e
In this installation position the PFH
value of the
d
system (evaluation unit + read head) decreases
to 4.29 x 10
-8
4 / PL e
In this installation position the PFH
value for the
d
system (evaluation unit + read head) is the same
as that for the evaluation unit