Wiring
2
- You must have the possibility to switch off
individually each motor.
- Attach cables to prevent any contact with moving
parts.
- If the motor is used outdoors and if the power
supply cable is of the H05-VVF type, then run the
cable in a UV-resistant conduit, e.g. trunking.
Compatible transmitters
3
1 : 1/5 channels Wall Hz transmitter / Memory Hz
2 : 1/5 channels / SUN Mobile Hz transmitter
3 : Color Multi 16 / Timer Easy / Timer Multi transmitters
4 : Windy Hz Accel
5 : EOSUN Hz VS
Location of the PROG key on Hz transmitters:
Do not position the transmitter near metal in order to
avoid range losses.
End limit adjustement
4
If the installation includes several motors, only one motor is to be powered during this programming procedure
(4,1). It will eliminate interferences with the other motor during the procedure.
4.1-Learning mode:
- Switch the motor ON.
- Simultaneously press the UP and DOWN keys of a Hz transmitter. The
motor will run for 0,5 second in one direction, then in the other. The transmitter
now controls the motor in unstable mode, move to stage 4.2
4.2- Checking the rotation direction:
Press the UP key of the transmitter:
a- If the motorized tube runs in the UP direction, move to next stage (4.3).
b- If the motorized tube runs in the DOWN direction, reverse the rotation direction by pressing the Stop key for at least 5
seconds. The motor will run for 0,5 second in one direction, then in the other direction. Move to the stage 4.3.
!
85 Nm max.
1
§4.3
5s.
N
L
PE
(12 transmitters max./3 sensors max. for one motor)
2
3
3
!
10 Nm max.
(DMI6 120 : 20Nm max.)
Blue
Brown
Green / yellow
4
5
4
5
ON
§4.3
2/5